18101382572
爱尔兰 TOF-Watch
SX肌松监测仪具有以下特点:
1、有自动探测传感器和刺激电极,大而清晰的显示界面,低电流模式可适用于持续或间断的肌松监测,提供了所有的刺激模式:单次刺激(ST)、四个成串刺激(TOF)、强直刺激(TET)、强直刺激后计数(PTC)、双短强直刺激(DBS).稳定电流设计保证刺激的可靠性,即便皮肤的电阻发生改变.校正功能也能简化刺激模式中对照颤搐高度的设定.
2、标配表面温度探头和神经定位功能;
3、随机术后专用分析软件。
TOF-Watch
SX肌松监测仪配置单
编号 名称 数量
01 肌松监测仪主机 1
02 刺激电极 1
03
加速度传感器 1
04 神经刺激探头 1
05 拇指固定器 1
06 数据传输缆线和接 1
07
软件安装盘 1
08 操作手册 1
09 温度探头 1
英文资料:
TOF-Watch
SX is the most advanced device in the TOF-Watch range of neuromuscular
transmission monitors. The instrument incorporates all features required for
routine daily use. Fully compliant with Good Clinical Practice guidelines, it is
equally suited for use in clinical studies.
NEW Optional Feature!
Now
compatible with Phillips medical systems monitors. Click to learn
more.
Flexible use
TOF-Watch SX can be used as a peripheral nerve
stimulator, as a nerve locator for local anesthesia or as a neuromuscular
monitor. And TOF-Watch SX can also be linked to a PC for real-time display of
data that can later be exported and printed for record
keeping.
Features
TOF-Watch SX is programmed to accommodate every type
of stimulation pattern currently in use:
Single twitch (ST) - at 0.1 or 1
Hz
Train Of Four (TOF)
Slow TOF (user programmable time intervals from 1
to 60 min.)
Tetanic stimulation (at 50 or 100 Hz)
Post Tetanic Count
(PTC)
Double Burst stimulation (DBS 3.3 and 3.2)
These patterns can also
be adjusted manually using the "P button."
A constant current feature
guarantees reliable stimulation even with increased skin resistance (up to 5
kOhm).
TOF-Watch SX has two automatic calibration modes, one at a user
predetermined current and one which establishes the supramaximal value of the
stimulation current. Manual gain adjustment is also available.
A
superficial temperature sensor completes the package.
TOF-Watch SX
presents all relevant data (twitches, body temperature, transducer sensitivity,
stimulation mode, etc.) on an easy-to-read LCD display.
TOF Link
TOF
Link, a fiber-optic cable facility, enables on-line data "dumping" from
TOF-Watch SX to a PC without reciprocal electromagnetic interference with other
OR or ICU appliances. During operations, data can be logged using the TOF-Watch
SX Monitor program. In this way, detailed and authentic operation records can be
created.
The TOF-Watch SX Monitor software makes a real-time data
accessible for further processing on a personal computer. Its two basic
functions are:
Logging and display of real-time recorded data on personal
computers
Exporting and printing of previous recorded data
Good Clinical
Practice conformity
During on-line data dumping, standard pre/programmed
comments or other user comments can be added to patient recordings. Such
comments can later be completed or changed. Program use is password controlled:
the password can only be assigned by a main
user.
Microprocessor-controlled Custom designed
LCD with
numerical presentation of twitch data
Automatic Calibration:
Automatic adjustment for optimal gain and 100% reference
Stimulation
Modes:
TOF (Train of Four)
PTC (Post Tetanic Count)
1 Hz twitch
0.1
Hz twitch
DBS 3.3 and 3.2 (Double burst)
Tetanic stimulation (Burst), 5
sec - 50 Hz or 100Hz
Output:
(accuracy ± 5% of display value)
Surface electrodes
Constant current, 0 - 60 mA (0 - 12 μC up to 5
kOhm
Monophasic, 200 μs pulse width
Needle electrodes
Constant current,
0 - 6 mA or (0 - 0.24 μC)
Monophasic, 40 μs pulse width
Transducer:
Acceleration transducer (accuracy ±5% of full scale value)
Battery:
9V Alkaline or NiCd (6LR61 / 6AM6)
Supply voltage:
9V=, 100 mA
max
Type:
BF
Weight:
Approximately .55 lbs. with
battery
Dimensions:
8 x 3.6 x 2 inches
Standard
Stimulation
cable for surface electrode
Acceleration transducer
Thermistor probe for
TOF-Watch SX only
Optional
Stimulation cable for local
anesthesia
Mounting bracket
Hand adapter
Arm board